1. what is 3 point calibration & 5 point calibration? 2. If we use hart communicator to set the LRV & URV of a smart transmitter, did we calibrate the transmitter? why? 3. Make a complet list if meterials needed to properly connect a pressure gauge to a steam pipe using 1/2 inch stainless steel tubing. The gauge connections is 1/2 inch NPT-M and the steam pipe tap has a 1/2 inch female coupling, compression fittings are use. 4. What are the tools in loop checking? 5. What would the ISA symbol of a square root extractor look like? 6. What would you do to completely prepare for the configuration? 7. What safety measures must you undertake when doing configuration? 8. what are the two most commonly use programming languages used when we configure a PLC? 9. What would you do if you accidentally skipped a step in the configuration procedure? 10. How would you know if the configuration were sucessful? 11. Name at least 3 selections available when we configure the burnout protection of a controller?
3 36465Post New EI Electrotechnical Institute Interview Questions
Is it possible to restrict the scope of a field/method of a class to the classes in the same namespace?
Give me an introduction about myself.iam a engineering student, i would like to know, wat is my qualification till my enginering is not yet completed?
which two panels can be used to change the label text of a button component? : Adobe flash
When to use ensemble learning?
Is 64gb ram enough for gaming?
why do hard water never produce foam when a soap is dissolved?
what are the gbx,gdb and other tools in linux for core dump,and how to configure stdout,stderr..what is the difference between stdout ,stderr and coredump. how to create core dump and view that one? please can anybody explain me?
Can you update the values of props?
What is bitwise operator in c#?
if no size is defined while creating the database, what size will the database have? : Sql server administration
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
What is front controller?
State the two differences between Built-In and Repository in Talend?
How to create an external dataset with sas code?
What is oledb in c#?