Hi Friends i need Electronics&Instrumentation Engg question papers for BARC written test by coming 20th May 2008 pls post ur use full info to kkumarei@gmail.com. Or for suggestions pls give one missed call to 9962122264
1951hi friends,im an instrumentation and contol engg student,can u hlp me of suggsting barc written question paper,my id is roysuvaranjan@gmail.com, cel no.9563591747
19971.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
2427installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
2127if differential pressure created by orifice falls below vapour pressure of liquid flowing through it what will happen
1 5518Post New BARC Instrumentation Interview Questions
What is the main purpose of google analytics?
What platforms do you currently work on at your desk?
How to set focus in reactjs?
Explain the key highlights of Apache Spark?
A blastomere was removed from an 8-cell human embryo, and its beta-globin gene was amplified by PCR. The beta-globin DNA was treated with an enzyme that cuts on either side of and within the normal allele (producing a small fragment), but not within the sickle cell allele (producing a large fragment). Electrophoresis of the treated DNA from the blastomere demonstrated the presence of both a large and small fragment derived from the beta-globin genes. How should you interpret this test?
What is cpu core in linux?
How do I find duplicates in multiple columns?
Describe the web server logs?
What are pre defined queries?
What is ‘good code’? What is ‘good design’?
what are the standard methods for HPLC?
How do you write a good objective?
What is windows cortana?
What language is lisp written in?
In html5, what is a microdata?