why C.T secondary are rated 5A generally?
Answer Posted / arun
The CT has separate primary and secondary windings. The
primary winding which consists of few turns of heavy wire,
wound on a laminated iron core is connected in series with
one of the line wires. The secondary winding consists of a
greater number of turns of a smaller size of wire. The
primary and secondary windings are wound on the same core.
The current rating of the primary winding of a CT is 100 A.
The primary winding has three turns and the secondary
winding has 60 turns. The secondary winding has the
standard current rating of 5A;therefore the ratio between
the primary and secondary current is 100/5 or 20/1.The
primary current is 20 times greater than the secondary
current. Since the secondary windings 60 turns and the
primary winding has 3 turns, the secondary winding has 20
times as many turns as the primary winding. For a CT the
ratio of primary to secondary currents is inversely
proportional to the ratio of primary to secondary
turns..this 5A s the standard fixed by the electricity
corporation and they folow t..so its a convention to follow
this standarrdd
| Is This Answer Correct ? | 11 Yes | 19 No |
Post New Answer View All Answers
How many gap between finger contact in a.c.b. and v.cb.?
by using pump duty, how we will can calculate the motor duty(KW)? is there any standard or formula.
How to use earthing on shipments.
What is the complete procedure of erection of electrical panel in industry
how unidirectional torque is produced in DC motor?
What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?
hey guys help me out.....what are the industrial uses/functions of nozzles in industries
substation+ plc system
our factory is going under construction mean time transformer 1000 kva 2 nos &load break swithch 12 kv & 4 nos 750 kva 2 nos & 380 kva 2 nos generator to be errcted.how to arrange earth pits &how to earth connect & neutral pit how to calculate in earth bit size.
HOW WE CAN REDUCE THE CIRCUIT COMPLEX OF STAR-DELTA STARTER .BECAUSE NOW WE USING ONE TIMER RELAY & THREE CONTACTOR FOR MAIN,STAR & DELTA ?IF ANY IDEAS PLZ POST.THANK U
what is R Core Transformer. how it differs from normal transformers. dont search in net and post the answer.
IF alternator SCR value will be high means what happen in alternator efficency at operating power factor of 0.8
I need a formula to calculate the size of cable as per load but in the terms of length. Please Reply me as i search lot of sites but i did not get the answer.
What will be the current drawn by HT motor, if low voltage is applied.. any formula to calculate the LT amps of HT motor.?
how we arrange the hv side with delta connection in case 33/11kv of transformer.