Why the generator rating in kva
Answer Posted / balaji
Generator is producer of Voltage and Current, we can
connect load as such draining full load current or half
load, even noload,but voltage remain moreover same.So it
willl rated in terms of product of V*I, secondly it gives a
electrical output for any Load(may Capacitor,Inductor &
resistor),so it is consider as Procuct of Voltage & Current
excluding powerfactor.
Whereas motor is machines coverts electrical Energy to
Mechanical energy, so it is rated in KW
| Is This Answer Correct ? | 172 Yes | 56 No |
Post New Answer View All Answers
how many parameters can integrate with fire alarm basically ?
what is the maintaining Cf in UPS.
how u measure/calculate renge of capacitor,capacitor has no any rating tag.what is the theory of measure of capacitons.
Write down the brushes of a de machine.
Where is the best place to mount distribution panel in a house.
How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?
what is the working process of over & under voltage relay.
why capacitive load is not used in routine life????any reason is there ??????
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
How to measure size of cable on a given load
What is the principal of motor?
In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.
i wasted one year for the job after completed my btech what can i say about 1year time in interview
What is the difference between PLC and Embeded system
What is the maximum number of swithes that can be connected in series up to down stream point in an LV Distribution system?