Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Explain Clearly Pahase and Neutral?

Answer Posted / prasad

In power system 3 phase supply with star connected winding
is used for supplying to single phase load. The star point
is called as Neutral since in perfectly balanced system the
voltage & current at neutral is zero.
In single phase load, the phase is supplying current while
return path for current is provided by neutral which is
basically other end of that phase with voltage almost equal
to zero

Is This Answer Correct ?    9 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what things to be considered when designing UPS

1781


Earth has zero potential then what would be the neutral potential ?

1432


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1753


When a single pase capacitor run motor- run on 230vac and Case(1)run with 8 Mfd 250 vac.capacitor , Case( 2) run with 8 Mfd 400vac capacitor. What is difference between both case regarding power ,efficiency etc?

2072


what may the reason for vector shift in a generator?

1876


is this the formula of building wiring to get the main breaker.Watts/volts*.8%+higher motor*(25%)=ampere. yes or no or send the correct formula for building wiring.

1716


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2382


What is the most accurate way of testing ELCB?ELCB is better than RCD?

3334


Why did lightening arrestor solid copper rod head is sharp on mobile tower top?

2024


what do u understand from filter factor of reactor?

1968


How to calculate phase to phase difference ?

2262


There is any especial requirement for motor to drive through with VFD?

2611


Usage of flywheel diode in relays

1931


i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.

2124


LT cable fault chaecking equipment and to find out the distance at what distence it failure . Name and where it is available?

2177