Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE Differance b/w on/off & pid control valve?

Answer Posted / ytd

ON/OFF CONTROL VALVE WORKING IN TWO MODE EITHER ON OR OFF.
In ON off control process has shoot up and down. This
process is not suitable for critical processes.
E.G.controlled heating / cooling for Annealing cycle.


PID control generally used in close loop process where
feedback of output is used to correct the input depend upon
the desired process.
S(o/p)= S(i/p)+/-(S(correction).
From this simple equation o/p signal is corrected but
depending upon the responce of the process `Diffential
gain' or integral gain is introduced and this simple
equation is modified.
Depending upon the process performance responce time ang
gain values are to be programmed in the PID controller.
Then PID controller follows the equation to make process
more controlled.

Is This Answer Correct ?    51 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How does a single acting, spring return ball valve actually work? Does it require continuous air supply? 

2086


how 3 out of 2 Logic/interlocks works? give brief explanation with help of diagram.

2256


What are the maximum packet size of: a) HART b) Profibus DP c)Profibus PA d) DeviceNet e) Foundation Fieldbus

5784


why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?

2168


What is difference between Ionization heat and bimetallic heat

1587


What is 1:1 redundancy ?

2328


Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...

2297


what is the input of digital counter during the the calibration time?

2268


how do we commission inergen system?

1903


Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.

2073


Why 4-20 amps is being used in instruments? Why cant we use any other range instead of 4-20 amps? Why only 4 amps is taken as lower limit and why 20 amps is taken as the higher limit?

1454


What is zener diode? What is voltage regulator?

1060


What is the PLC configuration in Cement industry?

3749


How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)

2538


How to calibrate an pressure gauge with yantrika test bench?

2845