Do you know how to measure the earth resistance? if so
explain it
Answer Posted / dinesh kumar
1.To measure earth resistance we use Earth Resistance
Meter/Megger.
2.In this Megger there are three terminals
Line,Nuetral&Earth.
3.Line & Nuetral are connected to two terminals and EARTH
Terminal to earth pit to be measured for resistance.
| Is This Answer Correct ? | 169 Yes | 77 No |
Post New Answer View All Answers
stand by earth fault protection (51G) for transformer rating 2000 kVA,Dyn11,33/0.400 V. LV NCT ratio and necessary resistor and metrosil values how to calculate
What are the applications of autotransformers?
HOW TO SELECT THE COPPER CABLE SIZES OF MOTORS,TRANSFORMERS?
why we use 630mm single core cable for transformer secondary side and why two neutral cable
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
What is the problem of internal failure in ship engine telegraph system norcontrol?
CAN WE CALCULATE THE NEGATIVE SEQUENCE AND ZERO SEQUENCE REACTANCE OF A GENERATOR USING ONLY ITS RATED VOLTAGE, KW, PF AND SYNCHRONOUS REACTANCE??? IF YES, THEN HOW??
Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend
what is differentila pilot supervision in the incomer control panel in the power station?
what is the meaning of osr in transformer.
size of condotory fron voltage level
although ckt breakers have taken the place of old fuse. But instead of it , these older ones are still used in the industries and homes ? why .... what are their advantages and disadvantages ? which one is leading and winning the race and competition ?
show the single line diagram of star delta starter with single phase preventer