What is the generating voltage of a power station consided
generally?
Answer Posted / sunny
generating voltage of power station is generally 11kv.
| Is This Answer Correct ? | 42 Yes | 8 No |
Post New Answer View All Answers
i want to know about torque of slip ring induction motor
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
neutral earth resistance testing is it possible for transformer while in load condition
why is the power generator connected as star earthed or star earthed through reactance and what its features ?
what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)
What is the minimum distance to be maintained in between HT panel and LT panel and Instrument panel as per IEC and NEC standards?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
Why is a plain induction motor unsuitable for wide speed control?
when ID fan will immediately stop through VFD what exactly cause and problem the ID fan
1.what is the reason for transformer and lightning arrester blast in 33kv system
what are the factors to be considered while design the breaker either HT or LT??
In siemens PLC, why do we want to move the data ?
how technical is calculated in 11kv line and lt line
Explain the role of a car driver as one of a feedback mechanism.
how to calculate the settings for shaft ct protn in hydro generators