What is meant by Active and reactive power?
Answer Posted / e.e
Active power means the power required for the heating and
rotating machines.
Reactive power means power required for building electric
and magnetic field.
kVA is apparent power(S), it consist of reactive power (Q
in var volt ampere reactive)))(for building electric and
magnetic fields) and active (P in W watts))(working power-
for heating, rotating machines,etc ) it is also thru that
S² = P² + Q².
| Is This Answer Correct ? | 29 Yes | 2 No |
Post New Answer View All Answers
i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.
sir, 3phase induction motor takes different pf and different KW in three phase while running,explain reason
Define steady state error.
list the type of vfd? wich is sutable for heating kiln?
You are of electrical field and you are going for software? Why
what is the min and max ohmic resistance for the earthing rod installed for lighting poles for street light network
How would you relate your key competencies to this position?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.
hai iam arunkumar. i have applied for an section enginner in rrb. i want lat 5 years solved question papers. if u have please sedn it to arun30682@gmail.com
Draw torque - speed curve and load curve of induction motor? mark operating point ?
Why we use Electrical energy rather than any other type of energy, mostly? Explain behavior of open secondary CT and short circuited secondary PT in energized condition?
What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.
What is pole of the system?
1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?