we re giviang 24v supply to transmitter and we getting
output from tx?now my question is wht we call this complete
proces?
Answer Posted / hiren
As output is seen from tx. It is open loop system . If tx stands for controlling application it is closed loop system.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How does work A temperature valve or fv control valve in process plz brief me
How many types of sensor
Square root calculation for dp flow transmitter?
pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)
Define cryogenic?
How flow can be measured with dp?
line up procedure for dp type flow transmitter?
What is the difference between modbus,fieldbus & profibus
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V
What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?
Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....
Explain the working principle of lvdt?
Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
centrifugal compressor interlock? Tell me the parameter at which compressor will trip