Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is full form of G.O.D in 11kv distribution?

Answer Posted / nagesh.patwari

It's Gang Operated Device, It is a most commonly used switch in small to medium substations, Pole mounted Substations is a gang-operated, air-break disconnect switch.

The “Gang” refers to the three phases being electrically or mechanically tied together so that the 3 phases open at the same time. The “Air Break” refers to a visible break in the air that allows crews to see that the switch is truly open.

Is This Answer Correct ?    17 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why we use Test Terminal Block in 11 KV and 33 KV electrical panels.

1325


What is the dc grounding system and what is diff between AC/DC grounding system?

2052


hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com

2862


what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?

1895


Name two types of electrical analogous for mechanical system.

1149


How to select the earthing transformer,for DELTA TO DELTA TRANSFORMER OR ALTERNATOR SIDE.Pls post your answers and calculation.

2320


Explain Creepage Distance of Insulator

2155


why do we use spark detector inside the slip ring brush compartment 0ona slip ring induction motor?

2033


why the neutral line is not giving shock to us if we touch it ?

1711


how to calculate short circuit current for the busbar

1431


how to set relay setting? and example calculation...

1968


What is center gravity load in substation?

2357


What is the relation between frequency and motor rpm?

1799


how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.

2072


What are the two major types of control system?

1041