In one plant id fan and fd fan are used for boiler. boiler is used to heat water after some days they install one tank to heat water by hot flue gases coming out from boiler and then hot flue gases are used to heat the air coming from fd fan before leaving out from chimney . but hot flue gases are not coming out from id fan what might be the reason?
Answer Posted / mayur mukaty
APH outer air is not more than 140 c and less than 130 c because of Sulphur due point.if APH efficiency goes down due to Soots deposit APH boiler outlet temp goes Increase on other side failure of Design or High CV fual feed to boiler also raised outlet temp. So that management decide for Recover heat by Heating of feed water that is thumb rule when you increase 3 c of feed water temp 1% increase Boiler efficiency. When you calculate Money terms you save lots of money
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is restricted earth fault explain in details
what is the basic use of power plant in equipment
What is LB-SR.
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
Why superheated are started before I'd and rd fan?
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
How We Calibrate the vaccum transmitter?
How to calculate power press toneage
can dp type level transmitter work in under vaccum condition
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
what is the trip circuit supervision in an electrical meaning?
By any way can we increase the B check hours from 300 to 500
What is difference between secondary Air & Tertiary Air and Their use.?