In one plant id fan and fd fan are used for boiler. boiler is used to heat water after some days they install one tank to heat water by hot flue gases coming out from boiler and then hot flue gases are used to heat the air coming from fd fan before leaving out from chimney . but hot flue gases are not coming out from id fan what might be the reason?
Answer Posted / mayur mukaty
APH outer air is not more than 140 c and less than 130 c because of Sulphur due point.if APH efficiency goes down due to Soots deposit APH boiler outlet temp goes Increase on other side failure of Design or High CV fual feed to boiler also raised outlet temp. So that management decide for Recover heat by Heating of feed water that is thumb rule when you increase 3 c of feed water temp 1% increase Boiler efficiency. When you calculate Money terms you save lots of money
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How We Calibrate the vaccum transmitter?
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
What is difference between secondary Air & Tertiary Air and Their use.?
what is the meaning of SST300 V56A in SIEMENS turbine
some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor
explain how the third harmonic content of the magnetising current affects transformer design
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
procedure of how to generate power in solar plant.
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
By any way can we increase the B check hours from 300 to 500
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
Why superheated are started before I'd and rd fan?
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?