Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why inverter rating in KVA?

Answer Posted / seank

True rating of a power supply is the amount of Voltage and Current that is flowing through the device.

If inverter rating is in kVA then the manufacturer is publishing ratings without assuming a power factor so the inverter could be used by rating on loads with potentially widely varying power factors.

This kVA would be best described by the Apparent Power(S).

If Apparent Power (S) is under estimated then it is possible the power supply will be undersized.

kVA to kW calculation
The real power P in kilowatts (kW) is equal to the apparent power S in kilovolt-amps (kVA), times the power factor PF:

P(kW) = S(kVA) × PF

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

When we use 3 terminal resistor?

1249


132/6.6πš”πšŸ πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš› πš—πšŽπšžπšπš›πšŠπš• πš‘πšŠπšœ πš˜πš—πšŽ πšŽπšŠπš›πšπš‘ πš™πš’πš πšπšŽπšπš’πšŒπšŠπšπšŽπš. 𝙸'𝚟𝚎 πšŠπš—πš˜πšπš‘πšŽπš› πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš› 𝚘𝚏 6.6πš”πšŸ/415𝚟 πšŒπšŠπš— 𝙸 πšŒπš˜πš—πš—πšŽπšŒπš πš—πšŽπšžπšπš›πšŠπš• 𝚝𝚘 πšœπšŠπš–πšŽ πšŽπšŠπš›πšπš‘ πš™πš’πš 𝚊𝚜 𝚘𝚏 13/6.πš”πšŸ πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš›?? π™Έπš π™½πš˜.. πšƒπš‘πšŽπš— πš πš‘πš’??

982


What is the unit of charge and current?

1166


Can you explain about pole discrepancy scheme

2184


why the pf of semiconductor device is improved the electrical devices

1847


how could we know the size of cable by physical view?

1628


what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.

1873


What is the classification of hydro projects based on installed capacity?

1197


In layman terms, what is the difference of Dielectric strength and dielectric constant when speaking of an insulating oil

2713


how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me

1906


How to measure current and voltage in an ELV circuit

4163


State thevenintheorem?

1068


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1886


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2300


Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632

2763