Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Partial Discharge test .Please specify that this
test can be test on 11/0.433 KV,630 KVA Transformer.

Answer Posted / khamesra.amit

PD is localised discharge which happens within the insulation because of small air pockets formed during winding insulation is being done in workshop. A Ultra high frequency signal is injected at the terminals which detects the frequeny and magnitude of electrical dischages. These values halps us in dentifying healthiness of insulation of the equipment.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is this the formula of building wiring to get the main breaker.Watts/volts*.8%+higher motor*(25%)=ampere. yes or no or send the correct formula for building wiring.

1708


What is the difference between electronic regulator and ordinary electrical rheostat regulator for fans?

1097


why connecting surge unit in contactor coil

1873


Showing results for capital, machinery, stock,wages, carriage in words, salaries, factory rent, repairs, fuel and power, buildings, debtors, sales, purchases, creditors, return outwords, return inwords, drawings, discount allowed, discount receivable, office expenses, bills payable, bills receivable, cash in hand, cash at bank, office rent comes under debit or credit

1520


What happened if C.T mount at any cable or Bus bar in wrong direction . C.T going on proper work or not . C,T direction is essential thing to properly work.

1773


What is different between resistance grounding system and resistance earthing system?

1143


explain all the classes with example

1958


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2710


WHAT IS VCB SAFETY

1248


1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor

4861


WHY BLADE & JOW OF ISOLETOR IN SUBSTATION?

5039


what is the purpose of silicon dropper used in battery charger?

7446


WHERE CAN I GET THE PREVIOUS QUESTION PAPERS OF Govt Polytechnic in deee 2nd year papers

2734


How to control motor gearbox speed and friquency? If length of cable and dia given, how to measure the voltage drop?

2032


in single phase converter, the no.of scr's conducting during overlap a)1 b)2 c)3 d)4

2063