what happens when the supply frequency to the tube light is
reduced to 25Hz....?
Answer Posted / mohandas
The choke is designed to generate a particular amount of high voltage when the starter contact breaks the supply to the choke. This high voltage discharges through the filament and in turn ionises the gas in the fluorescent tube. However when you reduce the frequency to 25Hz the high voltage produced by the choke will reduce considerably which may be insufficient to ionise the gas and the tube may not glow.
However if the frequency is reduced when the tube is already on and working the tube will continue to glow but with less luminosity.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What type of a DC motor would you use for a lift?
What is the method of estamating of cable, CB,MCB ?
why would amp draw on neutral wire be as much as amp draw on the hot leg.
In MEP Services what are parts of STP and what are there function?
Why it need to form a capcitor when it not been in use from three or two year. Plz describe it technically.
11 kv input, 66 kv input advantages
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
why we permissive overreach in distance protection.where it is applicable to use in long r short lines
i need mat lab program to find out the transmission line losses,regulation and losses
application s to shunt coil
What is oscillator circuit?
Do closed loop systems require manual input?
HOW CAN I GET 5CORE HO7 CABLE SIZE IF I HAVE 1800A?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Define newton's law of viscosity.