Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Whats meant by trivector meter where it is connected at the
substation?

Answer Posted / gundra chakrababu

The Trivector meter is a measuring instrument which measures the Active Power, Reactive Power and Total Energy consumed of a power line

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com

2922


what is the isolation transformer. what is the isolator?

2073


What is stacking factor? What is its approximate value?

1448


is it possible for different brand of H.V transformers to run or operate in parallel to each other? if so how much disturbance can this affact the H.V bus bar?

2138


what would happen if reactive power (kvar)is increased (more)or decreased (less)? how much exact reactive power should be maintained? and what should be done for that

2268


what is the saturation point of crgo lamination.

2238


sir vizag steel ka junior trainee ka paper kitne number ka ayega

2249


how to calculate the earth fault current

2507


How to calculate the size of earth cable to earth the neutral of UPS ?

1946


How to select HT/MV cable size ?

2473


what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.

2340


What is reactive power and where it is used.

1703


how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?

2143


how we design a pannel to start 10HP motor with the help of star delta starter?

2223


If i have two 3000 kW motors and the whole facility requires a 10 MVA transformer. What would be better installing two 5 MVA transformers(one for 1 motor ) or just a single 10 MVA transformer for both of them. Give reasons for your answer.

6141