what is start up vent valve ? why it is used in boiler?
Answer Posted / anandhan shanmugam
For starting time 25% valve open. After tg synchronisation the start-up vent close....
If any critical in boiler low temperature maintenance to open start up vent and increase the boiler outlet temperature.
Startup vent was- Airfail to close valve due to boiler safety purposes
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Name different parts of a pressure gauge.
kindly sent some demo question and answer
Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com
What are the error values can accepted in flow transmitter calibration?could u give any formula for this?
what is the reset offset and control system in instrumentation
anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me
How to Calibrate Ultrasonic Level Transmitter in field
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
how pressure transmitter work, what is its principal to measure and how its generate signal. for pressure transmitterinstallation which precautions must be taken ??
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
Using your own examples solve a problem involving normal table. (experimental method and analysis)
what is the protection system in solar turbine compressor
SOME OF YOUR QUESTIONS ARE NOT MAKING ANY SENSE SO TRY AND PUT IN A LITTLE BIT MORE EFFORT BEFORE YOU POST A QUESTION. WE WILL ONLY HELP THOSE WHO WE CAN SEE ARE TRYING TO HELP THEMSELVES.
If relative y axis vibration sensor is by passed, and relative x axis and absolute sensor is left working. how much monitoring i would have risked?
What is the minimum rating availalbe for weld neck orifice in market?