Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why do we use LPF wattmeter not UPF in the experiment of no load and blocked rotor test of 3phase slipring induction motor?

Answer Posted / saurabh wani

We use LPF only for no load test because at no load only reactive component of current flows in any machine. In 3 phase induction motor magnitude of reactive component current is more because of air gap. So power factor under no load operation is low and we use LPF wattmeter . If we use here UPF then it will give reading at time of starting only and after 3to 4 sec pointer will stable at zero no deflection.

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why we use ac supply as 415 volts instead of 415 v why we cant apply 230 v for dc

2356


When is lag lead compensator is required?

1070


What is a single phase autotransformer?

1041


How to check 11000/1.732 to 110/1.732 Potentila transformer (PT)?

2151


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

1964


Why 30kw 40 hp 4 pole 3ph induction motor over heated?any steps on reduction in heat?

1616


why starting current is high and resistance is almost 0 during the starting of motor dc motor...?

1685


what is the best method of grounding in 30 MW generator?

1966


mention hazard experienced during installation

1927


How is the percentage impedence of a transformer fixed at design stage???

1929


why single CT used in DOL starter power circuit?

2456


What was the Dg set radiator and lube oil temperatures trip in ACB

1778


can you send me the placement papers of electrical engg. from companis like NTPC,DRDO,IOCL,HPCL,BPCL etc.?If,plz send as soon as possible.Thanks.

2099


why only exciting current is shown not primary current in transformer???

1805


Why is better to have a minimum ceiling voltage of 250% than 160%?

1791