Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is OLTC AND RTCC and it's function?

Answer Posted / prakash

1.OLTC stands for On Load or Off load tap changer. It is generally used in power jobs.In case
of Off load tap changer we must have shut down the transformer to change the tap
position but in case of On load tap changer we does not need to shut down the
transformer we change the tap position in running status of a transformer .
2.In case of on load tap changer a resistance is used to hold the current when we change
the tap position in running status of transformer for a short duration of time when tap is
change from one position to another if we not use the resistance the current is flow
back & coil is burnt.


RTCC stands for Remote tap changer controller .It consists of various switch i.e voltage up & down button ,tap changer button etc . It is connected to the transformer via OLTC and generally kept inside the substation for controlling the transformer and also all the important alarms are fit in it .so, we carefully look after the transformer by the help of it at a distance from the transformer

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is dielectric loss?

1103


I want to ask that is there any relation between current denesity of copper and material purity. also is ther any standard which defines the standard current denesity of material.

1928


RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

2042


my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.

2017


Can you please explain creepage distance in detail, for a 6.6kV cable head what must the distance be and how do you determine it?

2845


why steady state stability limit is greater than transient stability limit ? How it can be explained ?

2888


why three phase capacitor takes unbalanced current in capacitor bank?

1460


Meaning of ingrace protection for motor.for ex IPXY

2875


What is stacking factor? What is its approximate value?

1367


how to calculate the torque of a motor?

2087


Earth has zero potential then what would be the neutral potential ?

1387


What is the exact formula for one weber of magnetic flux?

2107


how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids

1863


Explain mechanical rotational system?

1085


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1650