Why should we use Star-Delta connection in step down power
transformers?
Answer Posted / arindam
Delta is mainly used on low voltage side because its line voltage=phase voltage. if it is used on high voltage side due to high voltage in phase more insulation is required. But if it is star then its phase voltage = (1/√3)phase voltage. so if high voltage applied to line of star its phase value decrease by √3 times and comparetively less insulation is required. Hence star-delta is used for step down and delta-star is used for step up.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
what is the difference between the voltage of 5 volts capacitor and and 5volts battery?
which is better to use svc or synchronous condenser why ?
What is highest size of HT motor like 11 kv or 33 kv,and how to make it 750 rpm.i think the size will be very big.any idea ? pl. reply..
What is the most essential condition for the voltage build up for a d.c. Shunt generator?
why core is useful for a transformer ?and also in its operation ?
Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????
Dear all, I'm manikandan I have done by DIPLOMA EEE from 2011 , I have 5 years of experience from Power plant instrumentation field , which one field is give long life & which one field is best ,I confused a lot and also I'm studying AMIE, can I choose which department from Section B examination? pls tell me
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
can any tell me why slope 40% and 80% is calculated in differential protection?
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?
What is PQA???Applications........
How to calculate the multiplying factor for energy meter with ct ratio given
What are the three major categories of error?
Which type of motor is used in trains, what is the rating of supply used explain working principal?