Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between INVERTER and UPS?

Answer Posted / nagesh.patwari

In UPS after Mains failure power supply remains the same uninterrupted continuous without disturbance to the load.... While in inverter switching from Mains to the batteries will have momentary disturbance in power supply interruption will be observed

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

c++ write a program to use a fuction call "max"which accepts an intger arrey of size5.as an arrument and return the larger and smallest of the arrey to main without changing. the original changing of the original position of the element of the arrey.

1983


1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?

2216


How to calculate the efficiency of Turbo Generator(Alternator) in general....?

2971


A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?

2519


WHY BREAKER ARE USED IN SUBSTATIONS?

2281


at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.

1721


What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????

2004


What is the difference between Generator Differential Relay and Transformer Differential Relay?

2322


Why does the rotor rotate?

2345


tell me some type of questions throught which i can prepare for exam and do my best

2087


HOW TO TEST A LIGHTENING ARREST ER ?

2248


what are the specifications we must look at to select a relay for any capacity motor?

2076


What is the estimated total hydropower potential of india?

1191


what happen ehen synchronisation is done at below rated speed

2190


What is the basic principal, by which DC voltage level is increased more than the supplied AC voltage during conversion. As upto AC level it is contorrled by firing anlge but after maximum level how is it possible.Please clear picture. OR we have to supply the higher level AC?

2014