in 11kv/400v transformer when only one phase of 11kv supply
fails what happens to sec voltage and why
Answer Posted / suresh
HT side one phase fails means secondary side unbalance voltages coming ,that means upstream side breaker will trip within time limit.
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
How can we calculate the motor frame sizes?
what is the physical connection of a analog i/p to a analog i/p module (ab plc)and through a analog o/p module(ab plc) to a analog o/p . and how all the process control by scada
how can we phase identification in a distribution line,how we recognise that which phase is coming for a house hold connection.help me............
Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.
How to select batteries required for ups and the inverter if we Known load? And how AH is selected of battery?
how to select electrical equipment such as fuse,dg,transformer,motor,msb,wire,cable as per the connecting load..please mention any books to design,take licence
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
How to megger test 11 kV cable and the acceptance IR value
would the same effect be achieved by reversing the connection to one winding of the induction motor 3-phase?
Differentiate between kirchhoff’s first law and kirchhoff’s second law?
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
what is the difference between 4pole & 6pole DC Motors & give advantage ?
IN dc capacitive reactance is??
We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.
how to calculate the lightning arrester conductor @ no of earth pits required