in the farm,water tank of 8000 litter capacity situated in 12 meter above.Farm owner want to lift 7000 litter of water within 7 minute to water tank of 12 meter above.which motor having HP rating is suitable for pumping??

Answer Posted / alexey

P=dA/dt;
A=F*S=7000[kg]*10[m/s^2]*12[m]=0,84[MJ];
P=0.84[MJ]/(7*60[s])=2[kW]
P=2[kW]*1,34=2.68HP
Approximately 2.68HP motor will be enough

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How we can come to know the substation range,without go through any name plate ?

1501


what sort of general awareness questions are asked in o.n.g.c entrance exam?????????????????

4216


what is a bus riser in power system and why it is used

44229


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1564


what is v/f control in VFD?

1075






my question is how to answer the question "you are from b.tech eee background and why do you want to go for banking

890


Why 30kw 40 hp 4 pole 3ph induction motor over heated?any steps on reduction in heat?

1261


Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?

1539


what is allowable ac mixing in dc

1547


How to calculate phase to phase difference ?

1721


what is the size of ht cable of 33kv ht line and transformers ratings are 1 Mva and 5mva.please send formula also.

1007


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1249


what is saturation kit?which use above 15 kw motors panel side.

3581


Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com

1278


What is transient response?

670