Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we transmit the power at the voltage in the multiple of
11 or 1.1 like 11kv, 22kv, 66kv, 132kv...... some one told
me that it is due to fomr factor 1.1 of sine wave. its fine
but while transforming we can choose any voltage, so why
only multiple of 1.1 there also.......? plz tell me.

Answer Posted / raghunath

Due to the losses. Some power is loses due to the conductor resistance while transferring 11kV at one end we may get less than that cause of that we send 11kV to get 10 kV (nearly).

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Q) Write VBscript code along with QTPscript code in QTP tool for below scenario 1. Launch yahoo site(i know) 2. Do loogin(i know) 3.Click inbox link(i know) 4.Go to every page of mail box and count no.of read mails and no.of unread mails(i know) 5.Store page numbers, read mail count and unread mail count in a new excel file sheet 6.Create 10 types of graphs on that data 7.Do logout and close site(i know) 8.Save new excel files with graph

2553


I have 4 busbar of 1000 ampere. we use 4 busbar to make 4000 ampere in one phase.my problem is that when we applied 60% load on that then busbar produced high noise.what is the reason of that and how can i minimize that noise.

1784


What is the formula for calculating no-load current?

1154


what is magnetizing current test in power transformer

2825


pls tell what are doing the three phase motor star and delta connetion with circuit diagram and control wiring .

2060


how to select the automotive wire size by mathematical calculation. for xenon headlamp with ballast. the ballast given data voltage 10-17v,current permenant 6amp, run up phase is 15amp, peak at swicth on max 400micro sec is 40amp.the sum of cable resistance is 150mohm.please provide referenc document if any for relating the peak at switch on current,time & wire wire size

2428


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1776


What kinds of decision are made about CT from it's Knee point(voltage & current)?

5214


what is the difference between circular wdg & ractangular wdg?

2099


why we use ac supply as 415 volts instead of 415 v why we cant apply 230 v for dc

2460


(1)Can earth and be conected together (2) what is the diferent between earth & neutral

1858


What is different type of Electrical curve and how it protects the equipment's while up-normal situation?

1877


What is the operating principle of turbo-generator.

2419


What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

6236


why we have to particulary use ACB for below ratings,even available of MCB,MCCB with that range ?

2984