What do you mean by S.F.U. unit? application of it.
Answer Posted / sunil kumar rout
sfu -switch fuse unit
it has combination of hrc fuse and a switch unit with different ratting.
when any short ckt hrc fuse is blown and its control ckt and power contactor trip with help of bmr,earth fault relay,ct operated relay,or any type of digital rlay. but in some cases switch unit not trip
it is a old model.
now a days mccb used.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?
what is the criteria for selecting fuse rating in 1phase, 2phase & 3phase welding sets?
3phase motor can be used as a Prime mover for alternator.
EXPLIAN THE IMPORTANCE OF POLY PHASE CIRCUIT.
how many single tension hardware are required on a double circuit transmission tower?
What is the permissable nutral current of three phase system as per IS standards?
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?
what questions are asked in the interview for the post of an electrical maintenance engineer in FMCG companies?
In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..
block diagram of 2 ups system connected in parallel mode?
Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method
The magnitude of sum of two sinusoidal av voltage is equal to 230 volt.the magnitude of each individual voltage is also equal to 230 volt.what must be the phase difference between voltages?
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses? the second question is-generation is depends on LV winding? or LV winding design for generation voltage?