Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the capcitor to be discharged after put in to operation
& why not inductor though the both elements stores energy?

Answer Posted / parth

In capacitor 2 plate between dielectric medium while capacitor in operation then its fist charge and after some time its discharge.due to the plate while in inductor in which wire turn is use in which flux is charge the indhuctor then as x'mer flux is remain max .whith drow required amount if current form supply and it's continue to connected with the ckt .where in case of capacitor if capacitor charge its contain short path or if remove souce then act like source.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is it possible to connect a safety device in to parallel?

2139


I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?

2210


What type of wiring series or parallel is used for conventional and addressable type FAS & why?

1798


How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.

2038


How earthing/grounding done in aeroplanes and ships.

3617


WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1906


Swg formulae

2017


i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula

2203


how we can calcultae the short circuit level for bus bar

2234


how to calculation increase power factor for single phase

2293


in india per day how much power is generated including all power station

1946


how you configure motorvision relay (L&T make)from DCS

4880


list the type of vfd? wich is sutable for heating kiln?

2054


one electromagnet is called

1910


Define delay time.

1083