Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Where do we consider the pressure in mbar & where do we consider the pressure in bar & why is it so ?

Answer Posted / samir

mBar and Bar are both pressure unit. As per our system pressure we used the desired unit range transmitter or switches. As example if we have to measure PA fan header pressure pressure it's range very low as 5-10 Kpa,eg; 50-100mabar. So here we can used a transmitter or switches in bar unit instead Bar.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is difference between HOT permit and cold permit

2283


Q-Explain the different load conditions that will produced different offset which may or may not be acceptable to thhe control function

2232


Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer

4712


what is scale factor of proximitor & unit of the vibration.

2175


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1947


Q- What are the application in which PNP transistor is preferred over NPN ?

3391


hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q

1936


what are procedure of sox-nox calibration

3032


What is motion balance principle?

1215


For what reason would you possibly be compelled to make use of a Smith Predictor. Explain the idea behind the operation of this device.

1978


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

2538


What is loop1 and loop2 in MTS LT?

3899


Why MUX JB's are using only Temperature Element in Fundation field bus?

2383


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2318


How do bending tubing provide better measurement than using tubing fittings such as elbows?

1987