Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

tell me about aliphatic acid estimation by hplc which columns can we use

Answer Posted / reddy

A colorimetric method for the determination of carboxylic acids based on the dicyclohexylcarbodiimide-coupled reaction of 2-nitrophenylhydrazine and carboxylic acids is described. The product of the reaction is extracted into aqueous sodium hydroxide to produce a blue color. This method is suitable for the analysis of aliphatic acids, but aromatic acids do not react under these conditions.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how you confirm the assay method?

830


how require to interprit the method precision data of hptlc?

873


What is the formula for relative diffrence for standard solution in solution stability in validation?

863


Which products will produce when acetic anhydride reacts with Ter-butanol, Sec-butanol, Iso butanol, Dimethylamine etc.

2912


How to set analyticl specification for combination products?

799


What is the calibration of uv process and preparation

2047


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1654


How to establish relative response factor for hplc. Why it is required?

1271


How can I develope method of dissolution by HPLC OR UV

2457


What are the primary considerations in extractables and Leachables ?

2320


Tell me something about Vitamin A test method by HPLC

2726


what are the guidelines for analytical method validations?

1151


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

2616


Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

1504


Why use only methanol,used determinationof moisture content not use other solvents

1458