Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is RTU with SCADA connection ?

Answer Posted / asmoorthi2000@gmail.com

RTU is a Remote terminal Unit which is reflecting the present status of the equipment in the SCADA. So an operator can do the controlling function of the equipment from the SCADA. Normally in a substation, the feeder status will show in the SCADA through the RTU so operator can do the open/close any breaker in the feeder by SCADA through RTU

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

2170


what is control supply rating of a machine

2040


what is the meaning of the symbol << >> put in transformer drawing

2049


what will be d.g. capacity to cater together for 14hp A.C. load & 3kw lighting load

2042


We have 90mX100m hangar with 16 no.of supporting pillar. It is required to provide power supply on all pillars. what is suggested earthing scheme for hangars.

2053


what is solkor relay and which condition it will act?

3398


How to detect voltage vector shifting in interconnection protection.

1960


What is the use of bundle conductors?

1234


What’s electric traction?

1192


why do we carry out winding resistance test?

2336


In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.

1816


DG cranking voltage?

4810


with out colour codeing on conductor how can be find what is r,what is b,what is y phases.....

2009


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1908


If a surge divertor is required to be protected by 32 amp C Curve Circuit breaker does this limit the amount of protection from surges that you will acheive

1833