Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why current coil has less number of turns compared to
pressure coil?

Answer Posted / ansuman

current coil have to measure current ; to achieve it less resistance is given by providing less number of turns in current coil.

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1920


How can we increase the capacity of Energy.?

2285


How to calculate per unit impedance of transformer?

2206


what is the acceptable value of TAN DELTA and dissipation factor for 11kV, 1.75HP Motor?.

4181


How to calculate energy stored in an inductance?

1147


How to Calculate Current Rating of SDFU (Switch Disconnector Fuse unit) for Protectionof Capacitor Bank connected to Busbar of 800Amp,in LV side of 11/0.433KV, 250KVA Transformer?

5401


1.why we are using blocks in withoutgaplightning arrester 2.why we ar using bushing in withoutgap lightning arrestor

2038


What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?

1522


How to check 11000/1.732 to 110/1.732 Potentila transformer (PT)?

2208


How many double suspension hardware fittings are required on a double circuit transmission tower?

2111


which stabilizer is better ? AVR, Servo Stabilizer, Static stabilizer etc & why explain it

2876


In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)

11834


how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???

2171


What is mean by hot and cold loop testing?

1096


in ring main system we use the isolater b/w transfer bus and main bus if we r not use isolatar than wat will be the effect in our sys.

2090