How to calculate the motor winding resistance ?
Answer Posted / bharat
In electric motor there are three windings.
U, V ,W ,respectively, so measuring of resistance of motor first. switch off electriacal system.
then take e Multimeter and set on Resistance / O'hm. then both cord of multimeter put on U-V winding.. and see the multimeter reading and note..
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks
The screw thread commonly used for transmission of motion is one of the following types of threads
explain me the relation between torque, frequency,speed,voltage and current in the 3 phase induction motor?
he compression ratio for a petrol engine generally lies between
Single line digram for 11 kV to distribution use go,la and do
how we design a pannel to start 10HP motor with the help of star delta starter?
what is high - pot test. what's its use?????
what is the use of current transformer in power transformer secondary side.?its connectyed in WTI
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
Name two low frequency oscillators?
What consists of 2 or more thermocouples to be connented series?
when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com
how we find transformer capacity by ohm
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
Is RTCC panel needs any control supply.