How to calculate the motor winding resistance ?
Answer Posted / bharat
In electric motor there are three windings.
U, V ,W ,respectively, so measuring of resistance of motor first. switch off electriacal system.
then take e Multimeter and set on Resistance / O'hm. then both cord of multimeter put on U-V winding.. and see the multimeter reading and note..
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
What do you mean by Frame 5 Gas Turbine as well as Mark II.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
If rotor works in clock wise what happens
In india, according to trade theory above 5 HP motor reqired star delta starter. But we R connect 11 KV motor with 14MW in Direct to line ( With VCB starter combination) Can U Guess, How it is possible ?????
i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.
What are the parameters of water ( Water quality )to be monitored in Centralised HVAC ( water cooler chillers )
What is the fault or needs to be done when frequency in ac drives is not changing?
Can Anyone suggest the Standards (IEC or IS) for selecting copper current density?
detailed procedure how we calculate cost for pcc m10 and rcc m20 including centering and labour excluding steel/ iron
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
What is the Good Earth resistance value of G.I & Cu. Chemical Earthing & Normal Pipe Earthing?
what are the differant std sizes of cable trenches?
What is the height of DA, DAL, DB, DC & DDE tower?
does any one know where we can purchase insulation oil for high voltage oil filled cables
Can anybody please refer the best and simple book for about Protection relays and in detail of all its protection ?