In case of motor Power Factor Generally We Apply A Capacitor
But How Can We Know That A Motor is Running On Very low Power
Factor And What Rating Of Capacitor We Have To Place And Tell
Me Conversion Of Micro Farad to KVAR>
Answer Posted / pv2766288
generally now a days power factor is maintained by APFC ( auto power factor control) panel. Here there is a provision for setting the PF say 0.99. Capacitors from the capacitor banks are automatically switched off & on as per the load to maintain the set power factor. As motors are always run through motor control panel. As for the individual motor, we have to maintain the load for a suitable PF. Also C = kVAR / (2 π f V2) in microfarad
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
WHAT R THE SAFETIES IN A HIGH TENSION PANEL N LOW TENSION PANEL. ALSO WAT SAFETIES R THERE IN A 200 KVA TRANSFORMER?
how to determine the cable size...pls explain me with the formula taking particular load....does the factors like impedance & short circuit rating influence the cable size, if so how....
What is difference between unity power factor wattmeter and upper power factor wattmeter? In short circuit test of transformer the wattmeter used is unity power factor type or upper power factor type wattmeter?
How can we calculate the KVA rating of a Distribution transformer from its core details?
-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.
a governer in an Ic engine controls the
How can we increase the capacity of Energy.?
Explain what are inter-poles and why they are required in a dc machine.
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
What is use of starter and choke in tube light
why you don not show protection and type of isolation in key single line diagram?
How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.
1.what is meaning of curve into a mcb. 2.what is basic reason changing of curve
What are the three constants associated with a steady state error?