Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In case of motor Power Factor Generally We Apply A Capacitor
But How Can We Know That A Motor is Running On Very low Power
Factor And What Rating Of Capacitor We Have To Place And Tell
Me Conversion Of Micro Farad to KVAR>

Answer Posted / pv2766288

generally now a days power factor is maintained by APFC ( auto power factor control) panel. Here there is a provision for setting the PF say 0.99. Capacitors from the capacitor banks are automatically switched off & on as per the load to maintain the set power factor. As motors are always run through motor control panel. As for the individual motor, we have to maintain the load for a suitable PF. Also C = kVAR / (2 π f V2) in microfarad

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I HAVE A INCOMING 100A MCCB TPN 25KA, CABLE LENGHT OF 80M 70MM CABLE SIZE FROM MAIN SUBBOARD TO NEW DB.BASE ON THE FAULT LEVEL SETTING OF 45KA.I WOULD LIKE TO FIND OUT 25KA ENOUGH KA. APPRECIATE IF SOMEBODY CAN ASSIST ME WITH FORMULA FOR THIS. FRM: JEFF

4037


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

1956


How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.

2331


What is servo lock in CNC how they work and if any parameter for them in CNC machine

5351


what is class of SPD and dittels of all class ?

2132


What is Fire Panel ? How it works ?

2072


transformer phasor diagram under load explain it?

2192


What are your personal skills and abilities for such a Master Course and your possible preparation to undertake this course?

2046


what is the function of capacitor duty contactor in an capacitor panel???

4150


to hook up ten 50 amp rv pedastels at a lenth of 600 feet from the service what size will my service need to be and the size of wire will I have to run to each pedastel in series??????

2092


in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?

2285


how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment

1575


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1683


from where the self excitrd induction generator get the power?why is the voltage regulation is poor of seig?

2282


all the technical question with answers pleas send your email id ramar_eee@yahoo.com

2029