Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between Tailing Factor & Asymmetry

Answer Posted / anuj grewal

Tailing Factor is same the symmetry factor and calculate by the formula

T= W/2A

Where,
W- width of peak at 5%
A- distance of front edge from center at 5%

Asymmetry is the unsimilarity of peak and calculate by the formula

As = BC/AB

Where,
BC- Distance of back edge from center at 10% height
AB- Distance of front edge from center at 10% height.

Is This Answer Correct ?    12 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

708


How to do regeneration of Metacarb Pb plus column?

2510


Difference between hlaf and rlaf

2052


why salisylic acid not using now days for disdolution calibration?

712


What is the difference between purge septum flow and column flow in gas chromatography?

2478


WHICH STANDARD WE USE IN SILICA ANALYSIS IN SILICA-GEL METHOD FOR SOLID SAMPLE

2074


Did anybody have method for acetyl cysteine effervescnce tablet

2198


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1907


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1796


HI,I CLEARED BOB CLERK EXAM. MY INTERVIEW WILL BE ON 9TH OCTOBER,2010.PLEASE SEND ME INTERVIEW QUESTIONS AND ANSWERS. THANK YOU.

2186


why digestion require in icpms?

726


What is the requirement for brazil in the analytical method vslidation comparr to ich?

696


how to calibrate hplc & gc

4458


is it nessesary to do solution stability for 7 days?

718


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4001