Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are using (-24VDC) and where we r using plz tell me

Answer Posted / mugil

In Vibration Monitoring System -24V DC is using to Proximity sensor(Bently Naveda).
Because PNP transistor is used in this proximity sensor.The PNP transistor bsae voltage is negative 24v supply.That's why -24v DC supply is using.
When the probe is in air it will have no induced voltage
so all -24 voltage without induced voltage will return back.

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain types of valves?

1051


How to calibrate an pressure gauge with yantrika test bench?

2900


TEMPERATURE VARIATION FOR FREQUENTLY.

2042


Any one can help me to identified, how can we interchange the device in FF

2779


I want to buy a seal kit of a pneumatic power cylinder.But I don't know it's specification.So please help me to know its specification.

1930


How to Calibrate Vortex Flow transmitter in field

1263


What is intrinsic safety mean.

1902


What is the reason PT speed not incresed in gas turbine?

2393


In bently nevada vibration monitoring system,what is the reason to maintain the Resistance of the probe + extension cable equal to 95 ohm? If possible explain the basic principle of measurement with detail electronic circuits.

2951


Please can anybody help for control valve sizing step by step procedure?

2119


how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

2677


i hav applied for the post of engg. in iocl so please require the past test papers fro instrumentation engg please please help me and send me the papers or tell me the pattern and type of ques asked in examination......

2043


What is the difference between working pressure and calibration pressure of a control valve

3054


which type of signal used in instrument?

9833


what is the electrical operation procedure for switching on 27.6MVA electric furnace.

2025