what is the difference between megger and earth tester?
Answer Posted / abel tamang
megger is an electrical instrument which measures the resistance of the insulation whereas earth tester is also an electrical instrument by which we measure earth resistance...
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
Why is negative feedback invariably preferred in closed loop system?
why need to be maintain power factor for industrial customer?
what is basic difference betmeen normal & flame proof motor??
how we calculate the withstansing current capacity of wires&cables?
from generating station If 400v LT line length is 1000m how much voltage is drop and how do i calculate it? which cable will be use for this line?
Sir, plz tell me how droop setting is done in parellel operation od DG set ? please give practical example ?
how to conduct dc resistance test for rotor of an alternator and how to measure the rotor dc resistance value theoritically?
dear sir/madam i want to get some knowledge about RRB EXAMINATION(section engineer) 1- what is minimum cut off 2- wht portion is major portion . 3- can any body provide Sample paper. thanks & regards ashish
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
how unidirectional torque is produced in DC motor?
What is the efficiency during maximum power transfer?
how to find Harmonics and types as per the equipemnts
What is mean 2XWY
I completed iti in2004 I was worked in A grade contractor can I get c licence