Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Actually why the transformers ate rated in KVA.?

Answer Posted / pradyumna171

Transformer gives apparent power,it is the supply power to load and the power actually used by the load is the real power/true power/active power. Apparent power of 100 KVA has capacity to give 100 KW resistive load and for inductive load of o.8 pf it give 80 KW,and at 0.7 pf the same has capacity to give 70 KW . but the manufacturing company does not know which type of load to be connected across the transformer,therefore in simple we can say " DUE TO UNKNOWN POWER FACTOR THE TRANSFORMER ARE RATED IN KVA" and it is meaning less discuss about Iron loss & copper loss because the Inverted and UPS are rated in KVA but there is no iron loss & copper loss And in other hand in DC Generator there is Iron loss &copper loss but it is rated in KW not in KVA, because there is no angle between current and voltage(pf) in DC supply N.B transformer capacity -transformer iron loss & copper loss = transformer efficiency in KVA
PRADYUMNA CHANDRS PANDA
Mob No. 9437917849

Is This Answer Correct ?    22 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is ATS & RING MAIN UNIT in Distribution System?And its Function.

1916


No load tap changing transformer working

1582


what kn of disc is used in 33kv,132kv,220kv,400kv,800kv transmission line

3237


why US countries maintains 110v and 60HZ

2123


what is the soft starter principle? how is connection diagram? what is the procedure for checking the connection?

2110


some basic standard questions on transformer.

1724


What is effect of over voltage and under voltage on ACB

1877


How to calculate VA rating for CT or PT or Control Transformer?

2794


in star-delta tranformer,if the input of star connection is 400/7v 3 kva then what is the output of delta connection?

2066


which stabilizer is better ? AVR, Servo Stabilizer, Static stabilizer etc & why explain it

2804


comparision between ACB and VCB

2303


How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors

1878


What is s-domain and its significance?

1112


why a tester wont shock while testing the power in house

1789


how to Select its CORE in electrical cables based on its applications? or Application of various types of electrical cable based on it CORE?

3193