Actually why the transformers are rated in KVA.?
Answer Posted / pradyumna171
Transformer gives apparent power,it is the supply power to load and the power actually used by the load is the real power/true power/active power. Apparent power of 100 KVA has capacity to give 100 KW resistive load and for inductive load of o.8 pf it give 80 KW,and at 0.7 pf the same has capacity to give 70 KW . but the manufacturing company does not know which type of load to be connected across the transformer,therefore in simple we can say " DUE TO UNKNOWN POWER FACTOR THE TRANSFORMER ARE RATED IN KVA" and it is meaning less discuss about Iron loss & copper loss because the Inverted and UPS are rated in KVA but there is no iron loss & copper loss And in other hand in DC Generator there is Iron loss &copper loss but it is rated in KW not in KVA, because there is no angle between current and voltage(pf) in DC supply N:B . Transformer capacity -transformer iron loss & copper loss = transformer efficiency in KVA
PRADYUMNA PANDA BRG
Mob No. 9437917849
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor
In PFI plant one stage capacitor connection is directly connected(with out megnetic contact controll). but why?
Why the magneti fields are not passes from southpole to north pole
what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation
my diploma certificate in my higher education college
what is meant by neutral compensation factor and where it is used
Mention the disadvantages of low power factor?
A low wet bulb temperature indicates
What is frantic effect?
how we decide scurt (disc) of insulator with respect to kv rating
hi, i finished b.tech eee in 2008, im worked in dg sets mfg company , now i left job in 6months back, now again i want get job core side, how can i get? is there any couses we have learn to get better oppurtunity? /
How cmd is calculated in case of energy neters
PLEASE INFORM ABOUT THE IDEAL TEST RESULTS OF MAGNETIC BALANCE TEST OF TRANSFORMER 33/11 kv DELTA-STAR T/F
Can you tell me more about pu systems (per unit systems )calculation in large power systems? how to get the base for voltage and power in generator, transformator and transmission lines?
we have 15 ampere variyac but we want 30 ampere variyac what we do