Answer Posted / morsli
instrumentation job is to calibrate transmitters for exemple level ,pressure ,flow we use multimeter for the analog transmitter ,in smart transmitters we use a hart protocol .
other work is to calibrate pressure switch ,level switsh,temperature switch .
you adjust the valves switches ,on and off ,open and close.
you calibrate the valve with positionner ,pneumatic positionner or digital .
you deasmantel the pneumatic control valve ,and change the spare parts,the calibrate without positionner ,the open top at 3 psi and the close top at 15 psi.
you look for ground when there is a problem in instrument wiring.
you adjust the controller parameters PROPORTIONAL -INTEGRAL and DEREVATIVE when the controller is operating ,on line process.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
what is performance test.need defination
how to control pid
Specific gravity.
How will you calibrate PID controller? explain with example.
in sulfur process what is material of impulse line we use to connect with transmitter ? and does teflon affected by sulfur?
Give an example where you had aproblem on the job, and tell me how you solved the problem. and the finalvoutcome.
i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com
what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??
How to regulate the flow of Air in 4" line, with max flow of 330 nm3/hr and Pressure of 0.5 bar? please suggest the type of instrument required.
Why the ammonia and Nitric Acid level indicators is with millimeter ? and What is the conversion form millimeters that level indicator indicate to weight ?
I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.
please send me the inteview questions in IOCL
what is the difference between magnetic flow meter and mass flowmeter
what is compensation? temprature & pressure