During the main stator winding insulation testing (phase to ground)of 11kv alternator (Lerysomer) i found 0 and resistance with multimeter and found 20 killo ohm while the power cables are connected both end (Generator & VCB). In VCB PT (Potential transformer) are connected.
Please any body explain that method of insulation is correct or not? also describe of PT connections
Answer Posted / k.prakashchandra
Supposing that you have disconnected the neutral of GEN , you will measure the dc resistance of PT as the other end of it is earthed . 20 K ohm will be measured as 0 M ohm by the megger . If you want to test insulation of GEN , you have to isolate the winding from everything .
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Help need in transformer !? Hello Friends The parameters of 2300/230 v 50hz t/f is R1=0.286 ohm R`2=0.319 ohm Rc=240 ohm X1=0.73 ohm X`2=0.73 ohm Xm=49.2 ohm Secondary Load impedance ZL=0.387+J0.29 solve the exact equivalent circuit with normal voltage across primery.. I know every thing but i cant find CURRENT I1=? and I`2=? Please help me give solution or only Formula please please...
what material is the electrical housing wire made of? is there any difference for the telephone lines?
what is diff btw electric,magnetic & eletromagnetic field
what happen if generator of micro hydro running at only a small percentage of its capacity, as a comparison, if the diesel generator that runs on only a fraction of its capacity there will be a wet stacking
If the rated speed of a d.c. Shunt motor is1440 r.p.m, which method of speed control would you suggested to obtain a speed of 1500 r.p.m?
what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.
is it possible to say motor horsepower number without seeing name plate(when name plate damaged)
If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.
What is diversity factor in electric installations?
What is the most essential condition for the voltage build up for a d.c. Shunt generator?
What is the RMS and DFT principle of analogue maesurments. Which way they are advangages. where which princples give optimum results.
my question is how to answer the question "you are from b.tech eee background and why do you want to go for banking
3phase motor can be used as a Prime mover for alternator.
1.What is the range of stator resistance of 3-phase induction motor? 2.Two electrically operated vibro motors are foxed in parallel direction in vibrating feeders. what is the direction of both vibro motors?