dear friends,

we are use 130 hp load run with 0.98 power factor ( 38KVAR
capacitor connected ). if we need improve the the power
factor to 1 (unity). how much kvar capacitor to be add. have
any formula? please share with me.

Answer Posted / puneetpurohit1710

if u can get P.F= 1 u will get noble prize

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1435


Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station

1638


What are the types of the glands and difference between single and double compression type of cable Glands.

1749


What Is Sampling?

861


why and where we use early make & late break contacts in protection?

7841






Write the force balance equation of m ideal mass element.

830


If a rotary UPS is in line through grid power; What would be the impact on Power Factor if the load through rotary ups is 25% , 50% , 75% & 100%. Will the power factor reduce with less load?

1522


what is the diff. between x'mer , isolation x'mer & ultra-isolation x'mer ?????????????

1848


LT cable fault chaecking equipment and to find out the distance at what distence it failure . Name and where it is available?

1784


How to see the inductance in a transmission lines

1762


How to determine stage of Automatic Power factor controlling Relay(Apfcr)?

1788


Explain bypass capacitor?

762


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1518


use of choke in APFC panels

5082


I am applying for NTPC examination.Can we please provide previous paper to my mail prasad.chintala108340@gmail.com

1832