Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why using 4-20ma not using 0-20or why not using 1-
20ma???????

Answer Posted / rathod mukesh

0 - 20 ma range is not use in the instrumentaion as standard range because if we use 0 ma for zero process parameter value, if any reason loop wire become break although plc or micro controller get 0 Value at unkown process parameter value and its understand process is in healthy condition but actcully fault is occur in physical data(0-20 ma) transmission link . the plc or micro controller is not accept proper value of process prameter. And we cant define live zero of process parameter. Use to 4- 20 rane ma we easily define live zero.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Draw bode plot of any transfer function. Why is plotting bode necessary?

2433


Which is your favourite subject & explain any one topic of it.

9513


how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.

2412


what is RTV function in in process control?

3055


If a warning lamp will operate with the ground circuit is bypassed with a jumper wire to ground, what should you check?

2028


How to do gas analysers calibration in AUTO and Manually by using zero and span gas?

2300


why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V

2385


what is loop1 and loop2 in MTS LT?

4596


Which type of diagphram use in costic line,DM water line,natural gas line,oil line?

3867


Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?

1936


a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error

2236


in sulfur process what is material of impulse line we use to connect with transmitter ? and does teflon affected by sulfur?

2217


Why MUX JB's are using only Temperature Element in Fundation field bus?

2263


What are different types of control valves?

1523


Calibration procedure for water rotameters

2142