Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why using 4-20ma not using 0-20or why not using 1-
20ma???????

Answer Posted / rathod mukesh

0 - 20 ma range is not use in the instrumentaion as standard range because if we use 0 ma for zero process parameter value, if any reason loop wire become break although plc or micro controller get 0 Value at unkown process parameter value and its understand process is in healthy condition but actcully fault is occur in physical data(0-20 ma) transmission link . the plc or micro controller is not accept proper value of process prameter. And we cant define live zero of process parameter. Use to 4- 20 rane ma we easily define live zero.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain plc level and its type?

1407


Why thermo wells are used? What materials are used in thermo wells?

1169


PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear

2001


Why is the orifice tab provided?

1291


State bernoulli’s application.

1191


How we calculate orifice plat size???

1573


What is instrumentation technologists and mechanics?

1035


Programmable Logic control.

1997


How to calibrate RC Feeder system in thermal power station?,If any instrument available to calibrate it,ple inform me. make:stock,

3231


what is loop1 and loop2 in MTS LT?

4707


Valve positioner and actuators in detail.

1847


Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com

3262


How can i test procedure grounding for CAT-7 cable? Or How can we test procedure CAT-7 Cable Electrically safe?

3004


can anyone tell me about the basic concepts to consider before to start a PLC panel wiring

1980


hello sir/madam, I,Subramanian need 5yrs placement papers of officer trainee of Instrumentation technology.pls send to this mail id mani_nxtgen@yahoo.co.in please do the needful. with regards, subramanian.v

2268