What is the maximum advisable distance where it is required to interconnect a 500 KVA 480 V 3 ph transformer and the main panel or MCC ignoring the voltage droop affectation, does it is exist any standard about it?
Answer Posted / perladelsur
Thanks Mr VinotKumarkkp for your comment but I think there are other reasons like to reduce the shortcircuit inpedance toprotection accurancy and other effect that I am trying to find out
Bye
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
at what basis/standard we have to arrive the current density of aluminium/ copper in busbar?
How to select a transformer group to connect a 0,433 KV generation with 33 KV grid in bi directional flow of current
what is current check gurd relay?
What is the unit of charge and current?
Pls tell me whether we can use EN3A material for shafts of Permanent magnet alternator.What will be the effect of magnetic and nonmagnetic material for shafts on magnetic properties of PM rotor .
WHERE NEUTRAL WIRE IS CONNECTED AT DOMESTIC TO TRANSMISSION LINE(SINGLE PHASE TO THREE PHASE)
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
what is difference between 9kv 5ka surge arrester and 9kv 10ka surge arrester.
what happen when we add mentos in cold drink?& why?
I want to do a mini project. Now I'm studying in 6th semis tor EEE Engineering.
No load tap changing transformer working
What is transient response?
how we explain parallel paths armature winding?
how do u gauge the size of the cable ?for eg. consider a 300 sqmm L.T Cable.How do u determine the size of the cable seeing it pratically?
What is difference between SMC supportg and Glass Fibre Reinforced Plastic Support.