Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In the test for control of absorbance in UV calibration why
do we use only potassium dichromate and what is purpose of
taking a specified amount of 57.0-63.0mg?

Answer Posted / srinathsagar

UV range is 190-400nm so in this range potassium dichromate with sulfuric acid gives characteristic peaks(At 235,257,313 and 350nm)

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

2053


in each media we require to use SLS? how to proceed?

800


in api coa contains only process impurities and in product coa contains degradation impurities?

707


Which are the diffrent grades of api in pharma?

785


Tell me about analytical method validation in QC

6191


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1863


how can give the expiry period and restadardisation of volumetric solution

2603


Which parameters require to do in tech transfer?

767


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

783


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

2051


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1609


What is the formula for relative diffrence for standard solution in solution stability in validation?

814


Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

921


What is mean by PDR?

965


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2167