Answer Posted / banda saivarun
switch gair is used for switching operation like if any faults occurs the related equipment may damage to avoid that here we are using switching components like MCCB,FUSES,CIRCUITBREKERS,RCCB etc so with out switching devices there is no electrical system
Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
What is thresh hold value of current?
what are your career plans upon completion of the programme and the relevance of recity generation to your professional development?
What is the disadvantage in proportional controller?
1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?
which model T or pie model is prefarable in power syatem
what is the transformer rush current?
State Maximum Power Transfer theorem.
low frequency protection why recomend?
How many points does a Circuit can have?
what is the voltage between earth & neutral in 3 phase electrical connection.
Which device of PlC does share load between DG sets when DG are running in perallel?
how commomn gate triggering is given for TRIAC ? other thyristor wont be efffected?
Why LED light has advantage of rapid reflection ,although other lights alse reflect.? and this light is considered to be best for transmission usage in case of Free optics
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
PLZ EXPLAIN THE INTERLOCKING AND CONTROLLING OF CONTACTORS????HOW CAN I DO THAT?