we take dc motor,when we apply voltage in dc motor the current is flow.the armature carrying conductor take current and cut the main field. according to faraday's law rate of change of flux,emf is induced but oppose the emf according to lenz's law.this emf called back emf
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
A 11KV, 1200 A breaker combination fixed in a cubicle for HT motor.Is normally for 11 KV motor fuse is using? if Yes, What range fuse is required?
hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .
how to operate and maintenance of 1500 kva diesel generator set
what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?
True or false question. 1.The fuse provide phase and neutral 2.power loss in electrical circuit can take place in (resistance or inductance or capacitance). 3.two phase system each phase has separated by a phase difference of (90 or 180 or 270 or 45). 4.3 phase balanced star connected load neutral current shall be (line current or phase current or zero or unity)
Explain Continuous and Discrete signals?
what maximum range of star & delta in hp or kw ?
wHAT IS CAPACITANCE LATCHING? hOW TO CALCULATE CAPACITANCE LATCHING? hOW TO SOLVE THE PROBLEM IF CAPACITANCE LATCHING APPLIED?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
Can clean earth cable be considered as low current cable
what is high - pot test. what's its use?????
Explain about Leakage Test.
How to calculate per unit impedance of transformer?
I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?
Why 15Amp. MCB is suitable to carry load of 1.5Ton Ac please Explain?