Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why potassium dicromate use in calibration of UV VIIBLE
SPECTROCOPY ?

Answer Posted / vikram

k2cr2o7 in H2So4 can give more maximum in the UV-VIS region,(at 235,257,313,350,430nm)so that we can check the whole UV-VIS region with a single run.
k2cr2o7 itself is stable and available in high purity.In dilute perchloric acid solution,it has a linear response with temperature.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is mean by peak intigrity?

860


Why perchloric acid used for potentiometric titration

2629


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

664


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2775


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

3999


please explain about aluminium hydroxide assay

1089


function of detecter in hplc ,gc and spectroscopy? function of carrier gas in gc?

2605


Did anybody have method for acetyl cysteine effervescnce tablet

2198


why we are using benzene, anyline in acetic anhdride assay titration method?

2062


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

732


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1905


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1835


what is the purge flow & how to calculate

2557


why does used dry caffien in HPLC calibration?

1977


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1642