Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the range of using dol starter & star delta
starter.

Answer Posted / pawan

Till 5HP motors we use DOL starters . If we use beyond it,there will be a drip in the mains power supply.. Beyond 5HP, star delta is use as firstly motor operate in delta and thus its starting voltage is less(which is req. as in starting no back emf is there) after an instant it start operating in star as now motor has developed sufficient back emf to counter the voltage. Now the current is less(I/root3) as less current is beneficial reducing losses.. Now the ques. arises why only 5HP?Why not 5.2 or 5.5? The answer is its just a standard value.When it is tested beyond 5HP, drip is showing.. Thus the value 5HP.. Also motor are not available as 5.2 or 5.3 HP..So the standard value taken is 5HP...

Is This Answer Correct ?    2 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is meant by stator? What is meant by rotor?

1055


diff b/w normal grounding and resistance grounding

1866


what is meant by power and distribution transformer ?

1923


WHY THE RATINGS OF THE TRANSFORMER IS 33KV WHY NOT OTHER???

2320


If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?

1361


How to set a Zone 1 distance relay for distribution feeder?

1951


in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses?  the second question is-generation is depends on LV winding? or LV winding design for generation voltage?

1668


Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings

2022


current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer

1547


Define non-touching loop.

1263


How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend

2013


What is a differential amplifier?

1163


can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value

1810


brief notes on ammeters

1972


why ht motors are star connected?

1813