Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to check it good or bad capacitor

Answer Posted / harishdarade563

Firstly check out the rating of capacitor you want to check.According to voltage rating given on capacitor, apply the voltage to its two terminals(Note :Do not apply the voltage more than rating voltage,otherwise it will make a short circuit,less voltage can be applied) and then short those terminals.if spark between terminals is observed it is good otherwise it is bad.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

EHV current carrying parts need to have smooth finish,then how can a 245kv GIS with emery finish can run so long?

1822


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1906


i want to apper for apgenco or aptransco or related can any one sugest me where can i get previous papers of thouse exams

3252


what is the relation between knowing of the distance between power transformer and the capacitor feeder in case of parallel operation

1924


In case of HV test on medium voltage cables, BS is asking for 4 U0 where as IEC is asking for 3.5 U0. Can any one advise me how this 3.5 times or 4 times U0 is derived?

1642


How to calculate the no of Ceiling fan (1200mm sweep) per unit area?

1974


What would be the size of wire used for 2 Ton of window A.C?

1848


What happened when voltage will half value of current ...

1563


Why we use ups battery and dsdb battery in thermal power plant

2030


List of equipments required foe industrial repair lab.

1849


what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?

2344


What is the tension required for the 25000 CFM AHU belt

2418


how to interlock 3 incomer-ACB,1 buscoupler ACB,... pls answer this question and if possible send me the ckt diagram..haifriends2910@gmail.com

2832


How is efficiency of DG set calculated? At many places I found the efficiency to be mentioned in percentage. But at some other places I found kWH/ litres. I want to know how dimensionless percentage value is arrived at?

1869


Explain what is clipper and clamper circuits?

1122