In a coal fired boiler furnace temp. is high but super
heater out let temp. low what reason for this?
Answer Posted / y v subba rao
Final super heater inlet steam temperature is well below than flue gas temperature of that zone(400degrees). Steam travels trough super heater coils with higher velocity(may be 25m/sec) as per the boiler design to meet the steam requirement of turbine. Hence the pretension time of steam is very less in super heater zone. More over there is always a temperature difference across the tube thickness. Due to this reasons super heater out let steam temperature is always much below than flue gas temperature in that zone. However the boiler itself will be designed in such a way.
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
what is restricted earth fault explain in details
what is the difference between compensated & normal drum level in boiler drum?
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
LAPT working in alternator / generator
How We Calibrate the vaccum transmitter?
what is the trip circuit supervision in an electrical meaning?
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
How do you consider that you can improve and what assistance do you need to achieve this
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
operation
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?