Answer Posted / riaz abbasi
To transfer electrical energy from one place to another magnetic feild is required, and user of this magnetic fields are Transformers cores, generator flux, Motor flux, Iron core, inductors. to create this magnetic flux generator has to produce the Reactive power, and by controlling the exciting voltage we produce the reactive power. out of total generating capacity we produce 10-20 reactive power or in other words power factor reduce from 1 to 0.8, if more reactive demands appears than generator can import the reactive power and hence to compromise in the less active power generation and similarly power factor will go down, but generator is not for this purpose to facilitate each reactive power demand of system, so local capacitor banks are usually recommended if more reactive power appears.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is ratio of copper wire size and current ?
how we can calculate power factor in single phase & three phase ?thank u
how to compare with Relay settings for HT< panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps
How to size Air Circuit breaker (ACB)? What is the most important factors?
If a shunt Dynamo has induced emf 100V and 0.4 ohm resistance and battery of accumulator of open circuit emf 110V and 0.5 Ohm resistance are in parallel what is common terminal potential difference?
IN MY SYSTEM THERE IS ONLY OVER CURRENT EARTH FAULT RELAY IS AVAILABLE. FOR THE UNBALANCE SENSING IS THERE ANY RELAY IS AVAILABLE? THE SAME CTs WHICH ARE USED FOR THE OVER CURRENT EARTH FAULT RELAY CAN USE FOR UNBALANCE ALSO?
Why do power lines not short out when they fall into water?
According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.
what is maxemo work permit procedure
what is the use of piston rings in the engine used for a generator...........
what are the differant std sizes of cable trenches?
if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side
Formulae for calculating the transmission line losses for different voltage levels
why the check zone and main zone are used for Busbar Protn. scheem?
how can i get the formula to find out the cable size if i know the load of main fuse protection.